DS47L uTrust ScramblePad TS Reader

Search

Introduction


This document details the Physical Access Control Reader uTrust Scramblepad TS and its basic Operational and installation procedures.

Reader

Functionality


uTrust Scramblepad TS is a physical access control smart card reader that can read HF and LF contactless credentials, conforming to the following standards: ISO 14443 A & B, ISO15693 with a Randomly displayed keypad pin entry for additional security. The reader can interface with an access control system equipped with a RS-Hirsch serial interface. Only Listed Identiv control units are compatible for use with the DS47L-SSP-TS.

Reader Parts


a. Front/Top Casing

b. Rear view with back plate

Product details


Product Name

uTrust Scramblepad TS

Model Name

DS47L-SSP-TS

Device Type

RFID reader, 13.56MHz (HF) / 125 KHz (LF), keypad
Physical Access control Reader (accessory equipment).

Type of equipment

Suitable for Indoor use

Interface Type

Phoenix connectors

Voltage Rating

28V DC

Current Rating @28 V

240 mA

Communication protocol

RS-HIRSCH protocol

Specifications


Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), local codes, and the authorities having jurisdiction.

Model

Operating Voltage

Current @ 12V

Operating temp

Operating Humidity

Model

Operating Voltage

Current @ 12V

Operating temp

Operating Humidity

 

DS47L-SSP-TS

 

28 VDC

 

240 mA

 

0 to +49C

 

85 +/-5 % RH

  • Class 2 power source with 28VDC to be used to power the reader.

  • Only listed Identiv control units are compatible for use with the DS47L-SSP-TS.

Power up and Testing


1 Turn power on
Beep sound comes.


2 Present a card
HF card, LF card
The green LED glows when passed, RED LED when failed with a short Beep.


3 Press Start Key
Scrambling display with buzzer tone & displays scrambled key.

This is the default reader behavior.

Label


Installation


  • Install the respective mounting box in to the wall.

  • Take the cable from the backside of the reader as per the pin outs in the label drawing.

  • Fix the four screws at the corner into the mounting box.

  • Fix the bezel on the top of the installed reader.

Certifications

FCC


This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.

  • Increase the separation between the equipment and receiver.

  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

  • Consult the dealer or an experienced radio/TV technician for help.


Information to user
Changes or modifications not expressly approved by Identiv could void the user's authority to operate the equipment.

IC


This device complies with Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including interference that may cause undesired operation of the device.

UL 294 and UL 1076

Access Control Performance Levels


Destructive attack

Level IV

Line Security

Level I

Endurance

Level I

Standby Power

Level I

  • For UL 1076, the reader was assessed for the acknowledgement signal annunciation while interfacing to the Listed Identiv Mx series control unit via RS-HIRSCH protocol.