8330 uTrust Touch Secure Scramblepad Reader
Introduction
Â
This document details the Physical Access Control Reader uTrust TS Scramblepad and its user instruction and installation procedures.
Reader
Functionality
TS Scramblepad reader is a physical access control smart card reader that can read HF and LF contactless credentials, conforming to the following standards: ISO 14443 A & B, ISO15693 with a randomly displayed keypad PIN entry for additional security. The reader can interface with an access control system equipped with a Wiegand or RS-485 serial interface.
Reader View
a. Front/Top Casing
b. Rear view with back plate
Product details
Product Name | uTrust TS Scramblepad |
Model Name | 8330 |
Device Type | RFID reader, 13.56 MHz (HF) / 125 KHz (LF), keypad |
Type of Equipment | Suitable for indoor use |
Interface Type | Phoenix connectors and RJ45 |
Voltage Rating (8130ABC) | 7 - 16VDC (or) 55VDC on RJ45 Connector (PoE) |
Current Rating @ 12V | Peak Current - 425 mA Average Current - 355 mA |
Current Rating via PoE | Maximum Current - 80 mA |
Communication Protocol | Wiegand, RS-485 (2wire - Half Duplex), 10BaseT ETH |
Specifications
Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), local codes, and the authorities having jurisdiction.
Model | Operating Voltage | Current @ 12V | Operating temp | Operating Humidity |
---|---|---|---|---|
  8330 | 7 - 16VDC | Av - 355 mA @ 12V |   0 to +49C |   85 +/-5 % RH |
PoE @ 55VDC | Max. - 80 mA |
Class 2 power supply with 7 - 16VDC to be used to power the reader
PoE sourcing equipment shall be UL Listed (Altronix Model Netway8)
When the readers use PoE as a power source, the power input wiring from the control unit (i.e. Red and Black for 8330) shall be disconnected
The maximum length of the Ethernet cable when using PoE as the power source in UL installations is limited to 30 meters (98.5 feet)
Rated current at different operating voltages
Voltage (V) | Average Current (mA) | Peak Current (mA) |
---|---|---|
7V | 490 mA | 570 mA |
8V | 520 mA | 600 mA |
10V | 465 mA | 553 mA |
12V | 355 mA | 433 mA |
14V | 301 mA | 364 mA |
16V | 262 mA | 320 mA |
Label
-SHIELD - should be connected to the cable shield.
During wiring, make sure that the +VDC lines does not make contact with any other cables, as it might affect reader functionality/cause damage to the reader.
Power up and Testing
1 Turn power on
The LED blinks 3 times green with a long beep, then turns red.
2 Present a card
The LED blinks green, and a short beep is emitted.
3 Press Start Key
Scrambling display with buzzer tone & displays scrambled key.
4 RJ45 Ethernet cable
Reader can be powered from PoE. Communication happens through Ethernet also.
5 Wiegand / RS-485
Communication to the Panel is done through Wiegand / RS-485 / OSDP.
This is the default reader behavior.
Installation
All cabling and wiring shall be UL Listed and/or UL Recognized.
Install the respective mounting box in to the wall
Take the cable from the backside of the reader as per the pin outs in the label drawing
Fix the four screws at the corner into the mounting box
Fix the bezel on the top of the casing
Certifications
FCC
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna
Increase the separation between the equipment and receiver
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
Consult the dealer or an experienced radio/TV technician for help
Information to user
Changes or modifications not expressly approved by Identiv could void the user's authority to operate the equipment.
IC
This device complies with Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including interference that may cause undesired operation of the device.
UL 294 and UL 1076
Communication via Wiegand and OSDP was evaluated by UL and serves as the interfaces between the reader and panel
Communication via Ethernet was not evaluated by UL
The maximum length of the Ethernet cable when using PoE as the power source in UL installations is limited to 30 meters (98.5 feet)
When the reader is powered by a supply other than Identiv Mx series controller, the power supply should be a UL 294 and 1076 listed , class 2 supply
For UL 1076, the reader was assessed for the acknowledgment signal annunciation while interfacing to the Listed Identiv Mx series control unit via Wiegand and OSDP only
Access Control Performance Levels
Destructive attack | Level IV |
Line Security | Level I |
Endurance | Level I |
Standby Power | Level I |
Â