Table of Contents | ||
---|---|---|
|
CMD 301: ADD EXPANSION LINE MODULE INPUT OR RELAY TO STANDARD CONTROL ZONE
...
NN
1 All Users
2 Momentary Access
3 Unlock / Relock
4 All Access
5 Control
6 Lock Down / Lock Open
7 Alarm Mask / Unmask / Cancel / Deadman
8 Passwords
9 Users Inside
10 Tagged Users
11 Alerted Users
12 Temporary-Day Users
13 Use Count Users
14 Absentee Rule Users
15 Unreconstructed Records
STYLE
1 User Codes
2 User Temporary-Days
3 Use Count (also prints Temp Days and Absentee Info where needed)
4 Absentee Rule
5 User Tracking Status
6 Deadman Time
7 Option Flags
8 Print All Fields
Description:
Use this command to print a single user or a range of users, by family—the NN user functions—and formatted in a specified report STYLE.
All v7 options are marked in italics.
Example:
START 330 * 4 * 1 * 50 * 60 #
...
DTLM3/MELM3 - 1 Line Module Input, 1 RQE Input, 1 Tamper Input
DTLM
The screw terminals on each DTLM are labeled as follows: HI LO is the terminal for connection to the DIGI*TRAC controller's Line Module Input.
Observe polarity: HI to HI, LO to LO. The terminal labeled 1 is for the Alarm Sensor, the terminal labeled 2 is the RQE Device and the terminal labeled 3 is the Tamper Switch.
MELM
The flying leads on each MELM are color coded as follows: White for HI and Black for LO.
...