Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. In System Manager, click Maintenance to go to the Maintenance panel.

  2. Click the Update Software tab.

  3. Check the box next to the name of the appliance to select it.

  4. Click Inspect. Check the Status column to verify that the system is in a ready state:

    • “OK” is displayed if the system is operating normally and ready to be upgraded.

    • “Unauthorized” will be displayed if the current user is not authorized to upgrade software on the selected server.

    • “Unreachable” will be displayed if the system is not in a state where it can be upgraded.

  5. Click Send Update.

    Image RemovedImage Added
  6. In the Choose 3VR Update File window, locate the software update file, named Appliance-VIMS-7.0.X.XXXXX-en-us.3pa (where the Xs represent the software version and build number):

    • If you are connected to the VIP Appliance with a laptop or over the network, navigate to the drive on your computer where you have saved the unzipped 3VR download package. Browse to the update file and click to select it.

    • If you are connected to the VIP Appliance with a monitor, mouse, and keyboard, browse to the USB drive or CD containing the update file and click to select the file.

  7. Click OK. System Manager will transfer the selected update file to the appliance. The Status column will show the status of the transfer as it progresses.

  8. When the transfer is complete, the Status column for the appliance will show “Ready to Update” with the name of the update file.

Updating Appliance

  1. Click Update.

    Image RemovedImage Added

    The Status column will show the status of the update as it progresses.

  2. When the update is complete, the Messages panel will show the appliance’s name and IP address followed by “Done”

...

  1. In System Manager, click Maintenance to go to the Maintenance panel.

  2. Click the Update Software tab.

    Image RemovedImage Added
  3. Check the box next to the Enterprise Appliance. The Enterprise Appliance is indicated by an icon with three green cubes:

  4. Click Inspect. Check the Status column to verify that the system is in a ready state:

    • OK” is displayed if the system is operating normally and ready to be upgraded.

    • Unauthorized” will be displayed if the current user is not authorized to upgrade software on the selected server.

    • Unreachable” will be displayed if the system is not in a state where it can be updated.

  5. Click Update. In the Choose 3VR Update File window, locate the software update file, named Appliance- VIMS-7.0.X.XXXXX-en-us.3pa (where the Xs represent the software version and build number).

  6. Click OK. The update will immediately begin processing.

  7. When the update is complete, the Status column will say “Done” next to the Enterprise Appliance.

  8. Close System Manager.

...

  1. Launch System Manager.

  2. Click Maintenance to go to the Maintenance panel.

  3. Click the Update Software tab.

  4. Click Clear All to deselect the VIP Enterprise Appliance.

  5. Click Select All to select all appliances except the Enterprise.

  6. Click Inspect. Check the Status column to verify that the appliances are in a ready state:

    • OK” is displayed if the system is operating normally and ready to be upgraded.

    • Unauthorized” will be displayed if the current user is not authorized to upgrade software on the selected server.

    • Unreachable” will be displayed if the system is not in a state where it can be upgraded.

  7. Click Send Update.

    Image RemovedImage Added
  8. In the Choose 3VR Update File window, locate the software update file, named Appliance- VIMS-7.0.X.XXXXX-en-us.3pa (where the Xs represent the software version and build number).

  9. Click OK.

...