Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 13 Next »

Introduction


This document details the Physical Access Control Reader TouchSecure® and its basic operational and installation procedures. It covers the details of the Wall mount form-factor reader.
Model: Connectivity/Standard WM.

The reader comes in two variants for interfacing with the control panel:

  • Pigtail – 8100ABP, 8110ABP.

  • Phoenix connectors – 8100ABT, 8110ABT, 8130ABC.

  • P-refers to Pigtail, T- refers to Terminal (Phoenix header).

The reader comes in three variants in functionality

  • Standard HF Only - 8100ABP, 8100ABT.

  • Standard HF LF - 8110ABP, 8110ABT.

  • Connectivity HF LF - 8130ABC.

  • P-refers to Pigtail, T- refers to Terminal (Phoenix header), C- refers to connectivity.

  • In connectivity, only Terminal version is available.

Reader

Functionality


TouchSecure® is a physical access reader that can read HF and LF contactless credentials .The reader can interface with an access control system equipped with a Wiegand or RS485 serial interface Control Panel. It can also be interfaced with a Host Sever / Control Panel that supports Ethernet interface. User interfaces include RGB LED’s and Buzzer.

Reader Parts


The reader consists of the following main parts.

a.Touch Secure® reader with Casing

b.Back Plate

Reader Variants


Product details


Model Name

Connectivity/Standard Wall Mount

Device Type

RFID reader, 13.56MHz (HF) / 125 KHz (LF)
Physical Access control Reader (accessory equipment)

Type of equipment

Potted reader.
Suitable for Indoor use – 8130ABC and
Outdoor use – 8100ABP, 8100ABT, 8110ABP, 8110ABT

Interface Typ

Pigtail Cable (11 Core + Drain) or Phoenix connectors and RJ45

Voltage Rating (8130ABC)

6-16V DC or 48VDC on RJ45 Connector

Voltage Rating (All other models):

5-16V DC

Communication protocol

Wiegand, RS485 (2wire - Half Duplex), 10BaseT ETH

*Communication via Wiegand was evaluated by UL and serves as the interface between the reader and panel. Communication via RS485, OSDP or Ethernet was not evaluated by UL.

Specifications


Model

Operating Voltage

Current @ 12V

Operating temp

8100ABP
8100ABT
STANDARD HF ONLY

5-16 VDC

Refer graph in section “Rated current at different operating voltages”

-35 to +65 Deg C

8110ABP
8110ABT
HF LF

5-16 VDC

Refer graph in section “Rated current at different operating voltages”

8130ABC
HF LF
CONNECTIVITY

6-16 VDC

Refer graph in section “Rated current at different operating voltages”

0 to +49 Deg C

POE@ 48VDC

*POE sourcing equipment shall be UL 294 or UL 294B Listed with Class 2 output

  • When the readers use POE as a power source, the power input wiring from the control unit (i.e. Red and Black for 8130) shall be disconnected.

  • The maximum length of the Ethernet cable when using POE as the power source in UL installations is limited to 30 meters (98.5 feet).

  • There shall be no connections made to the RS-485 interface ( RS485+ and RS485-) for UL installations.

Standby Power is not provided by the Card Readers. The Standby Power Level is dependent on the external power source connected to the Card Reader.

  • All wiring or cables to the Card Readers shall be the shielded type

  • Only UL Listed POE sourcing equipment, or UL Listed power-limited power supply, or power-limited output from UL Listed control panel shall be used for the Power-Over- Ethernet feature. Cat 5e cabling is the minimum performance category recommended. These Card Readers when using POE feature are not intended for outside wiring as covered by Article 800 of the US National Electrical Code, NFPA 70.

Rated current at different operating voltages

Rated current for Model 8100


Voltage (V)

Average Current (mA)

Peak Current (mA)

5

147

166

8

150

178

10

116

138

12

97

114

14

83

100

16

73

86

Rated current for Model 8110


Voltage (V)

Average Current (mA)

Peak Current (mA)

5

147

166

8

150

178

10

116

138

12

97

114

14

83

100

16

73

86

Rated current for Model 8130

Rated current for 6-16V input

Voltage (V)

Average Current (mA)

Peak Current (mA)

6

280

308

8

261

292

10

217

257

12

172

202

14

148

173

16

131

156

Rated current for POE

Voltage (V)

Average Current (mA)

Peak Current (mA)

37

65

70

48

50

55

57

45

50

Installation details


Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), local codes, and the authorities having jurisdiction.

Parts List


  • TouchSecure® reader -1

  • Screws (A #6-18X1.5" SS ) - 4Nos – Back Plate mounting screws for Wall

  • Snake Eye Screw (SMF #6-32X5/16" SS) – 1 No- Top casing mounting security screw

  • Screws (SMF #6-32x3/8" SS) - 3 No’s - 1 casing to back plate mounting screw and 2 Junction Box mounting screws

  • Nylon anchor plug -4 Nos

  • 6 pin phoenix plug (Phoenix connector version only) – 2 Nos

  • Back Plate

Recommended Infrastructure


  • All cabling and wiring shall be UL Listed and/or UL Recognized

  • All readers shall be powered by UL listed POE sourcing equipment, UL listed power-limited power supply, or power-limited output from UL listed control panel

  • There shall be no connections made to the RS-485 interface ( RS485+ and RS485-) for UL installations

Cable Wiegand

22AWG Shielded cable. ( Cable P No : ALPHA WIRE, P/N 1299/10C)

Cable RS485

RS485 for 1000m** (4000ft) 24AWG STP

Cable RJ45

Cat5e / Cat6

Linear DC PS

5-16 V, 1A min.

** Tested in lab conditions up to 115Kbaud

Wiring Information

Cable Color codes for Pig Tail Reader


Table 1

& Do not connect when reader is powered by Power over Ethernet

Pin out for Phoenix Connector Reader


Table 2

Pin

Cable color

Description

Comment

P1.1

Orange

LED Green

P1.2

White

Data 1

P1.3

Green

Data 0

P1.4

Black

Drain

Connect drain to Cable shield

P1.5

Black + White

Gnd

P1.6

Red

Power

Do not connect when reader is powered by PoE

P2.1

Blue

Hold

P2.2

Violet

Tamper

P2.3

Gray

RS485-

P2.4

Pink

RS485+

P2.5

Yellow

Buzzer

P2.6

Brown

LED Red

During Wiring make sure that the +VDC lines does not make contact with any other cables, as it might affect reader functionality/ cause damage to the reader.

Mounting the Reader

Location of mounting holes on wall


Reader Installation Steps


a. Make holes on the wall as per the image above.
b. Insert the nylon screw plugs into the wall.
c. Connect the wires as per the Table 1 or Table 2.
d. TouchSecure® reader with Bottom Casing is to be now secured onto the wall using the Screws (A #6-18X1.5" SS ).
e. The top casing can be inserted onto the bottom casing.
f. Secure the Top and bottom casing by the Snake Eye Screw (SMF #6-32X5/16" SS).

Power up and Testing


  1. Turn power on
    The LED blinks 3 times green with a long beep, then turns red.

  2. Present a card
    The LED blinks green, and a short Beep is emitted .

This is the default reader behavior.

Certifications

FCC


This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.

  • Increase the separation between the equipment and receiver.

  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

  • Consult the dealer or an experienced radio/TV technician for help.

Information to user
Changes or modifications not expressly approved by Identiv could void the user's authority to operate the equipment.

IC


This Class B digital apparatus complies with Canadian ICES-003.
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including interference that may cause undesired operation of the device.

CE


Identiv hereby declares that the TouchSecure® Model: Connectivity WM device mentioned herein is in compliance with the essential requirements and other relevant portions of the Directive R&TTE 1999/5/EC.

UL 294


  • Communication via Wiegand was evaluated by UL and serves as the interface between the reader and panel

  • Communication via RS485 or OSDP is not permitted.

  • Communication via Ethernet was not evaluated by UL.

  • The maximum length of the Ethernet cable when using POE as the power source in UL installations is limited to 30 meters (98.5 feet).

UL 294 Access Control Performance Levels

Destructive attack

Level IV

Line Security

Level I

Endurance

Level I

Standby Power

Level I

  • No labels