Section 1: What is in the Box

Enterphone 19

Item

Part #

Quantity

Enterphone Unit

FR-50-21-125-AD2M

1

POTS Surge Protector

115243R3R

1

¼"–20 × 2" stainless steel self-tapping screw, Phillips head
(DIN ISO 7049 type H)

115280R3R

4

Dry Wall Anchor

115281R3R

2

Power Supply

115242R3R

1

Power Supply Barrel Connector

FR-221-2012

1

Installation Guide

1

Enterphone

Panel

19 Configuration Sheet

1

Keys

2

Enterphone IQ

Item

Part #

Quantity

Enterphone Unit

FR-50-21-50-AD2M

1

POTS Surge Protector

115243R3R

1

¼"–20 × 2" stainless steel self-tapping screw, Phillips head
(DIN ISO 7049 type H)

115280R3R

4

Dry Wall Anchor

115281R3R

2

Power Supply

115242R3R

1

Power Supply Barrel Connector

FR-221-2012

1

Installation Guide

1

Enterphone

Panel

IQ Configuration Sheet

1

Keys

2

Section 2: Accessories and Modifications

...

Check that your Enterphone product includes the following mounting hardware:

Item

Quantity

¼"–20 × 2" stainless steel self-tapping screw, Phillips head
(DIN ISO 7049 type H)

4

Drywall anchor

2

Identify the appropriate mounting diagram for your Enterphone product below.

Enterphone iQ

Image ModifiedImage Modified

Enterphone 19

Image ModifiedImage Modified

Choosing an appropriate install location

...

Note

DO NOT connect the product to power or power up the product yet.

Anchor
figure-1
figure-1

Image Modified

Anchor
figure-2
figure-2

Image Modified

Mount the product

Enterphone iQ

...

The cables used to connect power to Enterphone panels must meet the following requirements:

Length

Minimum Gauge

up to 15'

18 AWG

15' to 30'

16 AWG

Info

For Installers, “After installing the Enterphone and connecting power, attach a label to the power cable indicating the max voltage and current (12VDC and 5A)”.

...

Table 1: Technical Specifications

 

Screen Size

(inches)

Overall Dimensions (inches)

Weight

Operating Temperature

Power Requirements

Touch Function Capabilities

EnterphoneTM

19

19 in

20.87 x 16.47 x 4.0

21 lbs

0o – 49o C

12v DC, 60 VA min

YES

EnterphoneTM

iQ

10 in

16.5 x 12.5 x 3.4

16 lbs

0o – 49o C

12v DC, 60 VA min

NO


Scroll pagebreak

Figure 3: Terminal Block 1

Connections for Terminal Block 1 (TB1)

...

PIN

CONNECTOR

INPUT / OUTPUT / DESTINATION

1

16 VAC POWER

16V AC Power Supply (Not Used)

2

16 VAC POWER

16V AC Power Supply (Not Used)

3

+12 V BAT

12V DC From Power Supply (Factory Wired)

4

+12 V BAT

12V DC From Power Supply (Factory Wired)

5

NO

Relay 1 Normally Open

6

COM

Relay 1 Common

7

NC

Relay 1 Normally Closed

8

NO

Relay 2 Normally Open

9

COM

Relay 2 Common

10

NC

Relay 2 Normally Closed

11

D1

Door Trip D1 N/O to Door Trip Ground (To Door Switch Monitor For Relay 1 Relock on Door Open)

12

D2

Door Trip D2 N/O to Door Trip Ground (To Door Switch Monitor For Relay 2 Relock on Door Open)

13

GND

Door Trip Ground to Door Trip D1 and D2 (To Door Switch Monitor For Relock on Door Open)

14

B1

Exit Button B1 N/O to Exit Button Ground (To Exit Button for Relay 1 Remote Unlock)

15

B2

Exit Button B2 N/O to Exit Button Ground (To Exit Button for Relay 2 Remote Unlock)

16

GND

Exit Button Ground to B1 and B2 (To Exit Buttons for Remote Unlock)

17

Not Used

18

GND

RS-232 Communications Ground to CPU (Factory Wired)

19

TX

RS-232 TX Communications to CPU (Factory Wired)

20

RX

RS-232 RX Communications to CPU (Factory Wired)

21

NO

Postal Lock Switch Normally Open to Control Relay 1 Unlock (Postal Lock Sold Separately)

22

GND

Postal Lock Switch Ground to Control Relay 1 Unlock (Postal Lock Sold Separately)

Scroll pagebreak