Section 1: What is in the Box
Enterphone 19
Item | Part # | Quantity |
---|---|---|
Enterphone Unit | FR-50-21-125-AD2M | 1 |
POTS Surge Protector | 115243R3R | 1 |
¼"–20 × 2" stainless steel self-tapping screw, Phillips head | 115280R3R | 4 |
Dry Wall Anchor | 115281R3R | 2 |
Power Supply | 115242R3R | 1 |
Power Supply Barrel Connector | FR-221-2012 | 1 |
Installation Guide | 1 | |
Enterphone |
19 Configuration Sheet | 1 | |
Keys | 2 |
Enterphone IQ
Item | Part # | Quantity |
---|---|---|
Enterphone Unit | FR-50-21-50-AD2M | 1 |
POTS Surge Protector | 115243R3R | 1 |
¼"–20 × 2" stainless steel self-tapping screw, Phillips head | 115280R3R | 4 |
Dry Wall Anchor | 115281R3R | 2 |
Power Supply | 115242R3R | 1 |
Power Supply Barrel Connector | FR-221-2012 | 1 |
Installation Guide | 1 | |
Enterphone |
IQ Configuration Sheet | 1 | |
Keys | 2 |
Section 2: Accessories and Modifications
...
Check that your Enterphone product includes the following mounting hardware:
Item | Quantity |
---|---|
¼"–20 × 2" stainless steel self-tapping screw, Phillips head | 4 |
Drywall anchor | 2 |
Identify the appropriate mounting diagram for your Enterphone product below.
Enterphone iQ |
Enterphone 19 |
Choosing an appropriate install location
...
Note |
---|
DO NOT connect the product to power or power up the product yet. |
| ||||||
|
Mount the product
Enterphone iQ
...
The cables used to connect power to Enterphone panels must meet the following requirements:
Length | Minimum Gauge |
---|---|
up to 15' | 18 AWG |
15' to 30' | 16 AWG |
Info |
---|
For Installers, “After installing the Enterphone and connecting power, attach a label to the power cable indicating the max voltage and current (12VDC and 5A)”. |
...
Table 1: Technical Specifications
| Screen Size (inches) | Overall Dimensions (inches) | Weight | Operating Temperature | Power Requirements | Touch Function Capabilities |
EnterphoneTM 19 | 19 in | 20.87 x 16.47 x 4.0 | 21 lbs | 0o – 49o C | 12v DC, 60 VA min | YES |
EnterphoneTM iQ | 10 in | 16.5 x 12.5 x 3.4 | 16 lbs | 0o – 49o C | 12v DC, 60 VA min | NO |
Scroll pagebreak |
---|
Figure 3: Terminal Block 1
Connections for Terminal Block 1 (TB1)
...
PIN | CONNECTOR | INPUT / OUTPUT / DESTINATION |
---|---|---|
1 | 16 VAC POWER | 16V AC Power Supply (Not Used) |
2 | 16 VAC POWER | 16V AC Power Supply (Not Used) |
3 | +12 V BAT | 12V DC From Power Supply (Factory Wired) |
4 | +12 V BAT | 12V DC From Power Supply (Factory Wired) |
5 | NO | Relay 1 Normally Open |
6 | COM | Relay 1 Common |
7 | NC | Relay 1 Normally Closed |
8 | NO | Relay 2 Normally Open |
9 | COM | Relay 2 Common |
10 | NC | Relay 2 Normally Closed |
11 | D1 | Door Trip D1 N/O to Door Trip Ground (To Door Switch Monitor For Relay 1 Relock on Door Open) |
12 | D2 | Door Trip D2 N/O to Door Trip Ground (To Door Switch Monitor For Relay 2 Relock on Door Open) |
13 | GND | Door Trip Ground to Door Trip D1 and D2 (To Door Switch Monitor For Relock on Door Open) |
14 | B1 | Exit Button B1 N/O to Exit Button Ground (To Exit Button for Relay 1 Remote Unlock) |
15 | B2 | Exit Button B2 N/O to Exit Button Ground (To Exit Button for Relay 2 Remote Unlock) |
16 | GND | Exit Button Ground to B1 and B2 (To Exit Buttons for Remote Unlock) |
17 | Not Used | |
18 | GND | RS-232 Communications Ground to CPU (Factory Wired) |
19 | TX | RS-232 TX Communications to CPU (Factory Wired) |
20 | RX | RS-232 RX Communications to CPU (Factory Wired) |
21 | NO | Postal Lock Switch Normally Open to Control Relay 1 Unlock (Postal Lock Sold Separately) |
22 | GND | Postal Lock Switch Ground to Control Relay 1 Unlock (Postal Lock Sold Separately) |
Scroll pagebreak |
---|