Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

These connectors are part of Terminal Block 1.

...

PIN

CONNECTOR

INPUT / OUTPUT / DESTINATION

1

16 VAC POWER

16V AC Power Supply (Not Used)

2

16 V VAC POWER

16V AC Power Supply (Not Used)

3

+12 V BAT

12V DC From Power Supply (Factory Wired)

4

+12 V BAT

12V DC From Power Supply (Factory Wired)

5

NO

Relay 1 Normally Open

6

COM

Relay 1 Common

7

NC

Relay 1 Normally Closed

8

NO

Relay 2 Normally Open

9

COM

Relay 2 Common

10

NC

Relay 2 Normally Closed

11

D1

Door Trip D1 buttonN/O to Door Trip Ground (To DSM For Relay 1 Relock on Door Open)

12

D2

Door Trip D2 buttonN/O to Door Trip Ground (To DSM For Relay 2 Relock on Door Open)

13

GND

Door Trip Ground to Door Trip D1 and D2 ( To DSM For Relock on Door Open)

14

B1

Exit Button B1 N/O to Exit Button Ground (To Exit Button for Relay 1 Remote Unlock)

15

B2

Exit Button B2 N/O to Exit Button Ground (To Exit Button for Relay 2 Remote Unlock)

16

GND

Exit Button Ground to B1 and B2 (To Exit Button Remote Unlock)

17

Not Used

18

GND

RS-232 communications Ground to CPU (Factory Wired)

19

TX

RS-232 TX ButtonCommunications to CPU (Factory Wired)

20

RX

RS-232 RX ButtonCommunications to CPU (Factory Wired)

21

NO

Postal Lock Switch Normally Open to Control Relay 1 (Postal Lock Sold Separately)

22

GND

Postal Lock Switch Ground to Control Relay 1 (Postal Lock Sold Separately)

Scroll pagebreak