Software | Version |
---|---|
Velocity | 3.8.45.xxxx |
Velocity IDS Framework | 1.0.0.146 |
Bosch IDS Plugin | 1.0.3.198 |
...
To obtain a Bosch IDS plugin license, you will need a licensed Velocity 3.8.4 5 and a personal computer with email access so you can provide Identiv with information about your Velocity system and receive a license key.
...
To verify that the name and password you entered for the Velocity Services account was were correct, try to start the new service by right-clicking on the Velocity Service Control Manager icon (while the other Velocity Services are running) and choosing Start Velocity IDS Service from the pop-up menu.
...
Select the Object Library check box in the Main menu and the Object Library pane displays.
Expand the Topology folder till you reach the underlying panel, area, points, and output components that you need to place in the drawing are displayed.
Drag the required component from the selected folder to the drawing and carefully position them at the correct location.
If required, you can modify other features of the objects by right-clicking on the object.
The options in the pop-up menu:
...
Click Graphics in the Main menu.
In design mode, click Design->Draw and select IDS Area.
Draw the desired area on the map.
The Map IDS constructs a specific IDS panel Area and configures the IDS Area border and interior as shown.
Typically the IDS VIOs get plotted on the map as well, and you will draw the IDS Area around these plotted VIO objects as shown above.
...